product details

S sh single stage double suction centrifugal pump

S-type pump is to replace SH type single-stage double suction, horizontal split centrifugal pump, which is used to transport clean water and liquid with physical and chemical properties similar to water (the higher temperature of liquid does not exceed 80 ℃). It is suitable for water supply and drainage of factories, mines, cities, power stations, farmland drainage irrigation and various water conservancy projects. According to the requirements of the pump, such as SF, SM and so on.

021-62586878

Product overview

S-type pump is to replace SH type single-stage double suction, horizontal split centrifugal pump, which is used to transport clean water and liquid with physical and chemical properties similar to water (the higher temperature of liquid does not exceed 80 ℃). It is suitable for water supply and drainage of factories, mines, cities, power stations, farmland drainage irrigation and various water conservancy projects. According to the requirements of the pump, such as SF, SM and so on.

Model meaning

图片12.png

Performance range

Flow rate: 160 ~ 18000m3 / S

Lift: 12 ~ 125m

Structural features

S. The suction inlet and outlet of SM, SF and sy pumps are under the axis line of the water pump, perpendicular to the axis and in a horizontal direction. The pump shell is opened in the middle. There is no need to remove the water inlet and discharge pipes and the motor (or other motors) during maintenance. From the direction of the drive end to the pump, the water pump rotates clockwise, and the production can also rotate in the counter clockwise direction according to the needs. It should be specially proposed when ordering.

S. The main parts of SM, SF and sy pumps are: pump body, pump cover, impeller, shaft, double suction sealing ring, shaft sleeve, bearing, etc.

3. After static balance verification, the impeller is fixed by shaft sleeve and sleeve nut on both sides, and its axial position can be adjusted by sleeve nut. The axial force of the impeller is balanced by the symmetrical arrangement of its blades, and the residual axial force is borne by the bearing at the shaft end.

The pump shaft is supported by two single row radial ball bearings or four radial thrust ball bearings. The bearings are installed in the bearing bodies at both ends of the pump body and lubricated with grease or thin oil.

The pump is directly driven by the motor through the elastic sleeve pin coupling.

The shaft seal is a soft packing seal. In order to cool and lubricate the sealing cavity and prevent air from entering the pump, a packing ring is installed between the fillers. When the water pump works, a small amount of high-pressure water flows into the packing chamber through the trapezoidal groove on the open surface of the pump cover or the external unsealed pipe parts to play the role of water seal.


model

flow Q (m3/h)

lift H (m)

speed n (r/min)

power P(kw)

efficiency n (%)

NPSH (NPSH)r(m)

Shaft power

Motor power

100S90

80

90

2950

30.1

37

65

2.5

100S90A

72

75

2950

23

30

64

2.5

150S100

160

100

2950

59.8

75

73

3.5

150S78

160

78

2950

45

55

75.5

3.7

150S78A

144

62

2950

33.4

45

72.6

3.7

150S50

160

50

2950

27.3

37

80.4

3.9

150S50A

144

40

2950

20.0

30

75.5

3.9

150S50B

133

36

2950

18.0

22

72.5

3.9

200S95

280

95

2950

91.4

132

79.2

5.3

200S95A

270

85

2950

83.3

110

75

5.3

200S95B

260

75

2950

73.8

90

72

5.3

200S63

280

63

2950

58.3

75

82.7

5.8

200S63A

270

46

2950

45.1

55

75

5.8

200S42

280

42

2950

38.1

45

84.2

6

200S42A

270

36

2950

33.1

37

80

6

250S65

485

65

1450

109.2

132

78.6

3.1

250S65A

420

48

1450

88.5

90

77.7

3.1

250S39

485

39

1450

61.5

75

83.6

3.2

250S39A

468

30

1450

48.4

55

79

3.2

250S24

485

24

1450

36.9

45

85.8

3.5

250S24A

414

20

1450

27.2

37

83.3

3.5

250S14

485

14

1450

21.5

30

85.8

3.8

250S14A

432

11

1450

15.2

18.5

82.7

3.8

300S90

790

90

1450

243

320

79.6

4.2


型号

流量Q (m3/h)

扬程H (m)

转速n (r/min)

功率P(kw)

效率n (%)

汽蚀余量 (NPSH)r(m)

轴功率

电机功率

300S90A

756

78

1450

216.4

280

74.2

4.2

300S90B

720

67

1450

180

220

73

4.2

300S58

790

58

1450

147.9

200

84.2

4.4

300S58A

720

49

1450

118.0

160

82.5

4.4

300S58B

684

43

1450

100

132

80

4.4

300S32

790

32

1450

79

90

86.8

4.6

300S32A

720

26

1450

60.7

75

84

4.6

300S19

790

19

1450

47.1

55

86.8

5.2

300S19A

720

16

1450

39.2

45

80

5.2

300S12

790

12

1450

30.4

37

84.8

5.5

300S12A

684

10

1450

23.9

30

78.4

5.5

350S125

1260

125

1450

533

680

80.5

5.4

350S125A

1181

112

1450

461

570

78.2

5.4

350S125B

1098

96

1450

373

500

77

5.4

350S75

1260

75

1450

303

360

85.2

5.8

350S75A

1170

65

1450

244.4

280

84.2

5.8

350S75B

1080

55

1450

196.3

220

82.4

5.8

350S44

1260

44

1450

172.5

220

87.5

6.3

350S44A

1116

36

1450

129.5

160

84.5

6.3

350S26

1260

26

1450

102

132

87.5

6.7

350S26A

1116

21

1450

76.9

90

83.4

6.7

350S16

1260

16

1450

64.4

75

85.4

7.1

350S16A

1044

13

1450

47

55

78.3

7.1

400S90

1620

90

1450

473

560

84

6.2

400S90A

1460

73

1450

345

450

84

6.2


型号

流量Q (m3/h)

扬程H (m)

转速n (r/min)

功率P(kw)

效率n (%)

汽蚀余量 (NPSH)r(m)

轴功率

电机功率

400S90B

1300

58

1450

245

315

84

6.2

400S40

1080

40

970

140

185

85

5.1

400S40A

1007

33

970

107

160

84.5

5.1

400S40B

870

26

970

73.3

110

84

5.1

500S98

2020

98

970

678.1

800

79.5

4.1

500S98A

1872

83

970

539

630

78.5

4.1

500S98B

1746

74

970

450.1

560

78.7

4.1

500S59

2020

59

970

388.2

450

83.6

4.5

500S59A

1872

49

970

332.32

400

75.6

4.5

500S59B

1746

40

970

255.8

315

74

4.5

500S35

2020

35

970

218.2

280

83.6

4.8

500S35A

1746

27

970

150.6

220

75.6

4.8

500S22

2020

22

970

143.6

185

74

5.2

500S22A

1746

17

970

100.6

132

88.2

5.2

500S13

2020

13

970

85.7

110

85.2

5.7

600S22

3170

22

970

215.8

250

84.2

7

600S22A

2860

18

970

161.1

185

80.3

7

600S32

3170

32

970

310.4

355

83.4

7

600S32A

2850

26

970

229

280

88

7

600S47

3170

47

970

456

560

87

6.5

600S47A

2920

40

970

361

450

89

6.5

600S75

3170

75

970

736

900

88

6

600S75A

2920

65

970

600.2

710

89

6

600S75B

3170

55

970

477.5

560

88

6

600S100

2950

100

970

1015.6

1250

87

6



型号

流量Q (m3/h)

扬程H (m)

转速n (r/min)

功率P(kw)

效率n (%)

汽蚀余量 (NPSH)r(m)

轴功率

电机功率

600S100A

2710

90

970

875.4

1120

85

6

600S100B

3170

80

970

751.9

900

85

6

800S22

3000

22

730

370.2

450

84

7

800S22

2830

14

585

190.6

250

82

5

800S22A

5500

17

730

254.1

315

89

7

800S22A

4400

11

585

133.3

185

88

5

800S32

4830

32

730

538.5

630

87

74.5

800S32

3870

20

585

272.3

315

89

7

800S32A

5500

26

730

389

450

88

4.5

800S32A

3960

17

585

210.7

250

88

6.5

800S47

5500

47

730

782.2

1000

87

4.2

800S47

4400

30

585

403.9

450

90

6.5

800S47A

5070

40

730

621

710

89

4.2

800S47A

4060

25

585

314.1

355

89

6

800S76

5500

76

730

1293.6

1600

88

4.2

800S76

4400

49

585

674.9

800

88

6

800S76A

5080

65

730

1034

1250

87

6

800S76A

4070

42

585

541

630

86

4.2

800S76B

4680

55

730

824.7

1000

85

6

800S76B

3750

35

585

425.5

500

84

4


It is suitable for factories, mines, urban water supply, power stations, farmland irrigation and various water conservancy projects.

Assembly, disassembly, installation and disassembly:

Assembly of rotor parts: successively install impeller, shaft sleeve, shaft sleeve nut, packing sleeve, packing ring, packing gland, water retaining ring and bearing parts on pump shaft, and sleeve double suction sealing ring, and then install coupling.

Install the rotor parts on the pump body, adjust the axial position halo of the impeller to the middle of the double suction sealing rings on both sides, and fasten the bearing body cover with the fixed screws.

Install the packing, put the paper pad in the middle face, cover the pump cover, tighten the nut of the pump cover after tightening the stud pin, and finally install the material cover. However, do not press the packing too tightly. If the packing is too tight, the shaft sleeve will be heated and the power consumption will be large. If the packing is too loose, the liquid leakage will be large and the pump efficiency will be reduced.

After assembly, the pump shaft can be rotated by hand without rubbing, and the rotation is smooth and even. The disassembly can be carried out in reverse order according to the above assembly sequence. install

Check whether the centrifugal pump and motor are damaged.

The installation height of the pump, together with the hydraulic loss of the suction pipe and its speed, shall not be greater than the allowable suction height specified in the sample. The foundation size shall conform to the installation dimension of pump unit.

Installation sequence:

Place the water pump on the concrete foundation with embedded anchor bolts, correct the level by adjusting the wedge-shaped cushion block between them, and properly tighten the anchor bolts to prevent walking.

Pour concrete after the foundation and pump feet.

After the concrete is dry, tighten the anchor bolts and recheck the levelness of the water pump.

Correct the concentricity of motor shaft and water pump shaft. Make the two shafts in a straight line, the concentricity tolerance on the outer circle of the two shafts is 0.1 mm, and the non-uniformity tolerance of the end clearance along the circumference is 0.3 mm (check again after connecting the inlet and outlet water pipes and trial operation, and still meet the above requirements).

After checking that the rotation direction of the motor is consistent with that of the water pump, install the coupling and the connecting pin.

The water inlet and outlet pipes shall be supported by another bracket instead of the pump body.

The junction surface between the water pump and the pipeline should ensure good air tightness, especially for the water inlet pipeline, it must ensure strict air leakage, and there should be no possibility of trapping air on the device.

If the centrifugal pump is installed above the water level, the bottom valve can be installed in order to start the pump. Vacuum water diversion can also be used.

After the water pump and the water outlet pipeline, it is generally necessary to install gate valve and check valve (the lift less than 20 meters can not be used), and the check valve is installed behind the gate valve. The above installation method refers to the pump unit without common base.

Install the pump with a common base and adjust the level of the unit by adjusting the wedge pad between the base and the concrete foundation. Concrete is then poured in between them. The installation principle and requirements are the same as those of units without common base. Start, stop and run

1. Start and stop:

Before starting, rotate the pump rotor, which should be smooth and even.

Close the outlet valve and inject water into the pump (if there is no bottom valve, use vacuum pump to empty water) to ensure that the pump is full of water and no air entrapment.

If the pump is equipped with a vacuum gauge or a pressure gauge, turn off the rotary base connected with the pump, and then start the motor. After the speed is normal, open it again. Then gradually open the outlet gate valve. If the flow is too large, the gate valve can be properly turned down for adjustment; otherwise, if the flow is too small, open the gate valve.

Tighten the compression nut on the packing gland evenly to make the liquid leak out in drops. At the same time, pay attention to the temperature rise at the packing chamber.

When the pump is stopped, first close the cock of vacuum gauge and pressure gauge and the gate valve on the water outlet pipeline, and then turn off the power supply of the motor. If the ambient temperature is low, open the square plug at the bottom of the pump body to remove the water, so as to avoid freezing crack.

When it is not used for a long time, the water pump should be disassembled and the water on the other part should be wiped dry.

2. Operation:

The maximum temperature of water pump bearing should not exceed 75 ° C.

The amount of calcium base grease used for lubricating the bearing should be 1 / 3 ~ 1 / 2 of the bearing body space.

When the packing is worn, the packing gland can be pressed properly. If it is worn too much, it should be replaced.

Check the coupling parts regularly. Pay attention to the temperature rise of motor bearing.

In case of noise or other abnormal sound during operation, stop the machine immediately, check the cause and eliminate it.

If the rated speed of the pump is n, the flow rate is Q, the head is h, the shaft power is n, and the speed is reduced to N1. After the speed reduction, the flow, head and shaft power are Q1, H1 and N1 respectively

Q1=(n1/n)Q H1=(n1/n)²H N1=(n1/n)³N



Related information

Address:576 Wuding Road, Jing'an District, Shanghai

E-mail:info@xinguangminggroup.com